Fill in the dimensions for your job - length, width, height, or whatever fields the calculator asks for. All measurements are in metres and millimetres unless stated. Want a head start? Try a Quick Start Project Kit - pre-built job templates that load common specs in one click.
2
Adjust the waste allowance
Most calculators include a waste percentage field. The default is a recommended starting point - increase it for complex cuts or awkward layouts, reduce it for simple runs.
3
Click Calculate
Your material quantities appear instantly. Results show packs, bags, or units needed, plus the total area or volume for reference.
4
Add UK market prices (optional)
Click Get UK Market Prices if the option appears. This loads current trade rates and gives you a cost estimate alongside your quantities. You can edit any of the prices before calculating if your own rates differ.
5
Save to a project
Click Save to Project to store these results. You can create a new project or add the line to an existing one. You can save one project for free, or upgrade to a Pro account to store as many as you need with cloud backup and access across all your devices.
6
Print or export
Use the Print or Export CSV buttons to save your results. The print layout is clean and formatted for site use or handing to a client.
Your saved projects are under My Projects in the menu. Each project collects all your calculator results in one place - handy for pricing up a full job. You can freely amend any part of a project at any point. With a Pro account you can also send polished quotes to clients or material specs direct to subcontractors.
Calculate screed volume, cement bags, sand and drying times for sand & cement, liquid and fast-track screed systems.
How much screed do I need for a floor?
Multiply the floor area by the screed depth to get the volume. A 75 mm sand and cement screed over a 25 m² floor requires 25 x 0.075 = 1.875 m³ of screed material. A standard 1:3.5 cement-to-sharp-sand mix yields approximately 1.65 m³ per tonne of cement when mixed. Minimum screed depths under UK guidance are 65-75 mm for unbonded screeds, 40-50 mm for bonded screeds, and 25-40 mm for liquid screeds - depths depend on the screed type, whether underfloor heating pipes are embedded, and the final floor covering. UK Building Regulations Part L requires the screed layer above underfloor heating to be thermally efficient and to achieve the required floor U-value.
Concrete Screed Calculator
Add each area, choose your screed type and thickness, and get volumes, materials and drying times
Metric (m)Imperial (ft / in)
Areas
Unbonded on insulation: 65-75mm • Bonded to concrete: 25-40mm • UFH: min 65mm over pipes
Check your product datasheet - coverage depends on thickness and product
5%
Allow 5-10% for uneven sub-floors and mixing losses
Underfloor Heating Options
Tighter spacing = more heat output. Check UFH supplier spec.
Typically 80-120m per loop to avoid excessive pressure drop
Add perimeter for any custom-shaped areas above
Standard rolls are 25m or 50m - check supplier
Job Costing
Enter costs in your local currency.
UK Market PricesFills in the material cost fields with current UK market prices. You can review and edit each price before applying.
Results
Total Area
-
m²
Screed Volume
-
m²
Cement Bags
-
x 25kg bags
Sand
-
tonnes
UFH Pipe
-
- loops / ports
Edge Strip Rolls
-
rolls to order
Estimated Drying / Curing Times
-
Walk on
-
Light use / tiling
-
Full cure / floor covering
Drying times are estimates only and depend on temperature, humidity and ventilation. Always check with your screed supplier.
Multiply floor area by screed depth. A 75 mm screed over 25 m²: 25 x 0.075 = 1.875 m³. Sand-cement screed weighs approximately 2,000 kg/m³. A standard 1:3.5 mix uses approximately 350 kg cement + 1,200 kg sharp sand per m³. The calculator above gives exact quantities and bag counts.
What is the minimum screed depth?
Bonded screed (keyed to slab): minimum 25-40 mm. Unbonded screed (over polythene sheet): minimum 50-65 mm. Floating screed (over insulation): minimum 65-75 mm. Liquid screed (calcium sulphate): minimum 25-35 mm. Over UFH pipes: minimum 25-30 mm cover for sand-cement, 20-25 mm for liquid screed.
What is the difference between sand-cement screed and liquid screed?
Sand-cement screed: traditional semi-dry or wet mix, trowelled by hand, walkable in 24-48 hours, ready for floor coverings after ~4 weeks (1 day per mm). Liquid screed (calcium sulphate): pumpable, self-levelling, flatter finish, better for UFH, but requires 6-8 weeks drying time before floor coverings.
How long does screed take to dry before tiling or floor coverings?
Sand-cement screed: approximately 1 day per mm thickness (75 mm = ~75 days fully dry). Liquid screed: typically 6-8 weeks. Before tiling: screed must be below 75% RH. Before wood or carpet: below 65% RH. Always test with a hygrometer - do not rely on time estimates alone.
What Building Regulations apply to floor screeds?
Part A for loadbearing applications. Part L when used above insulation - ground floor maximum U-value 0.25 W/m²K in England. UFH systems must be designed to BS EN 1264 for efficient heat distribution. Part C requires waterproofing of screed in wet areas before tiling.
Can I screed over underfloor heating pipes?
Yes - standard method for in-screed UFH. Pipes are secured to insulation before screeding. Minimum cover above pipes: 25-30 mm (sand-cement) or 20-25 mm (liquid screed). Pressure-test pipes before screeding. Wait 28 days (sand-cement) for full strength before commissioning heating, then bring up to temperature gradually over several days.
UK Building RegulationsBS 8204 / Part C / Part M
Screed Type Guide
Sand & cement (site mixed) - Traditional 1:3 to 1:4.5 mix. Most common in UK domestic. Needs 24-48h before walking on, weeks to fully dry.
Sand & cement (bagged) - Pre-mixed for convenience. Same drying characteristics as site-mixed. Good for small areas or repairs.
Liquid anhydrite - Calcium sulphate-based. Pump-applied, self-levelling. Thinner minimum depths. Cannot be used in wet rooms. Needs priming before tiling.
Liquid cement - Cementitious flowing screed. Self-levelling, pump-applied. Can be used in wet rooms. Faster than traditional but slower than anhydrite.
Fast-track - Walk on in 4-6 hours. Tile in 24-48h. Premium cost but critical path savings on fast build programmes.
Thickness Guide
Bonded to concrete slab - 25-40mm. Must be mechanically keyed and primed.
Unbonded (on DPM) - 50-75mm minimum. Laid on a polythene slip membrane.
Floating (on insulation) - 65-75mm minimum for sand & cement. 35-45mm for liquid screed.
Underfloor heating - Min 65mm over pipe centres for sand & cement. Min 30-45mm for liquid screed. Check UFH supplier spec.
Liquid screed minimum - 35mm unbonded, 25mm bonded. Much thinner than traditional screed.
Drying Tips
Sand & cement screed needs adequate ventilation to dry. Open windows and use dehumidifiers - do not use direct heat in the first week.
Anhydrite screed must be forced-dried with heating and ventilation before tiling. A priming coat (diluted PVA or specialist primer) is essential before applying adhesive.
Test moisture content with a hygrometer before laying any floor covering - target below 75% RH for most adhesives and floor coverings.
Reviews
★★★★★
Did you find this calculator useful? We would love to hear what you think - your feedback helps us improve.
Trade Terms
Not sure what a term means? Our plain-English glossary covers 200+ building and trade terms.